Vortex tube


The vortex tube, also known as the Ranque-Hilsch vortex tube, is a mechanical device that separates a compressed gas into hot and cold streams. The gas emerging from the "hot" end can reach temperatures of 200 °C , and the gas emerging from the "cold end" can reach. It has no moving parts.
Pressurised gas is injected tangentially into a swirl chamber and accelerated to a high rate of rotation. Due to the conical nozzle at the end of the tube, only the outer shell of the compressed gas is allowed to escape at that end. The remainder of the gas is forced to return in an inner vortex of reduced diameter within the outer vortex.

Method of operation

To explain the temperature separation in a vortex tube, there are two main approaches:

Fundamental approach: the physics

This approach is based on first-principles physics alone and is not limited to vortex tubes only, but applies to moving gas in general. It shows that temperature separation in a moving gas is due only to enthalpy conservation in a moving frame of reference.
The thermal process in the vortex tube can be estimated in the following way: 1) The adiabatic expansion of the incoming gas, which cools the gas and turns its heat content into the kinetic energy of rotation. The total enthalpy, which is the sum of the enthalpy and the kinetic energy, is conserved. 2) The peripheric rotating gas flow moves towards the hot outlet. Here the heat recuperation effect takes place between the quickly rotating peripheric flow and the opposite slowly rotating axial flow. Here the heat transfers from axial flow to the peripheric one. 3) The kinetic energy of rotation turns into the heat by the means of the viscous dissipation. The temperature of the gas rises. As the total enthalpy has been increased during the heat recuperation process, this temperature is higher than the incoming gas. 4) Some of the hot gas leaves the hot outlet, carrying away the excess heat. 5) The rest of the gas turns towards the cold outlet. As it passes its way to the cold outlet, its heat energy is transferred to the peripheric flow. Although the temperature at the axis and at the periphery is about the same everywhere, the rotation is slower at the axis, so the total enthalpy is lower as well. 6) The low total enthalpy cooled gas from the axial flow leaves the cold outlet.
The main physical phenomenon of the vortex tube is the temperature separation between the cold vortex core and the warm vortex periphery. The "vortex tube effect" is fully explained with the work equation of Euler, also known as Euler's turbine equation, which can be written in its most general vectorial form as:
where is the total, or stagnation temperature of the rotating gas at radial position, the absolute gas velocity as observed from the stationary frame of reference is denoted with ; the angular velocity of the system is and is the isobaric heat capacity of the gas. This equation was published in 2012; it explains the fundamental operating principle of vortex tubes. The search for this explanation began in 1933 when the vortex tube was discovered and continued for more than 80 years.
The above equation is valid for an adiabatic turbine passage; it clearly shows that while gas moving towards the center is getting colder the peripheral gas in the passage is "getting faster". Therefore, vortex cooling is due to angular propulsion. The more the gas cools by reaching the center, the more rotational energy it delivers to the vortex and thus the vortex rotates even faster. This explanation stems directly from the law of energy conservation. Compressed gas at room temperature is expanded in order to gain speed through a nozzle; it then climbs the centrifugal barrier of rotation during which energy is also lost. The lost energy is delivered to the vortex, which speeds its rotation. In a vortex tube, the cylindrical surrounding wall confines the flow at periphery and thus forces conversion of kinetic into internal energy, which produces hot air at the hot exit.
Therefore, the vortex tube is a rotorless turboexpander. It consists of a rotorless radial inflow turbine and a rotorless centrifugal compressor. The work output of the turbine is converted into heat by the compressor at the hot end.

Phenomenological approach

This approach relies on observation and experimental data. It is specifically tailored to the geometrical shape of the vortex tube and the details of its flow and is designed to match the particular observables of the complex vortex tube flow, namely turbulence, acoustic phenomena, pressure fields, air velocities and many others. The earlier published models of the vortex tube are phenomenological. They are:
  1. Radial pressure difference: centrifugal compression and air expansion
  2. Radial transfer of angular momentum
  3. Radial acoustic streaming of energy
  4. Radial heat pumping
More on these models can be found in recent review articles on vortex tubes.
The phenomenological models were developed at an earlier time when the turbine equation of Euler was not thoroughly analyzed; in the engineering literature, this equation is studied mostly to show the work output of a turbine; while temperature analysis is not performed since turbine cooling has more limited application unlike power generation, which is the main application of turbines. Phenomenological studies of the vortex tube in the past have been useful in presenting empirical data. However, due to the complexity of the vortex flow this empirical approach was able to show only aspects of the effect but was unable to explain its operating principle. Dedicated to empirical details, for a long time the empirical studies made the vortex tube effect appear enigmatic and its explanation – a matter of debate.

History

The vortex tube was invented in 1931 by French physicist Georges J. Ranque. It was rediscovered by Paul Dirac in 1934 while he was searching for a device to perform isotope separation, see Helikon vortex separation process. German physicist improved the design and published a widely read paper in 1947 on the device, which he called a Wirbelrohr.
In 1954, Westley published a comprehensive survey entitled ‘‘A bibliography and survey of the vortex tube’’, which included over 100 references. In 1951 Curley and McGree, in 1956 Kalvinskas, in 1964 Dobratz, in 1972 Nash, and in 1979 Hellyar made important contribution to the RHVT literature by their extensive reviews on the vortex tube and its applications.
From 1952 to 1963, C. Darby Fulton, Jr. obtained four U.S. patents relating to the development of the vortex tube. In 1961, Fulton began manufacturing the vortex tube under the company name Fulton Cryogenics. Dr. Fulton sold the company to Vortec, Inc. The vortex tube was used to separate gas mixtures, oxygen and nitrogen, carbon dioxide and helium, carbon dioxide and air in 1967 by Linderstrom-Lang.
Vortex tubes also seem to work with liquids to some extent, as demonstrated by Hsueh and Swenson in a laboratory experiment where free body rotation occurs from the core and a thick boundary layer at the wall. Air is separated causing a cooler air stream coming out the exhaust hoping to chill as a refrigerator. In 1988 R. T. Balmer applied liquid water as the working medium. It was found that when the inlet pressure is high, for instance 20-50 bar, the heat energy separation process exists in incompressible vortex flow as well. Note that this separation is only due to heating; there is no longer cooling observed since cooling requires compressibility of the working fluid.

Efficiency

Vortex tubes have lower efficiency than traditional air conditioning equipment. They are commonly used for inexpensive spot cooling, when compressed air is available.

Applications

Current applications

Commercial vortex tubes are designed for industrial applications to produce a temperature drop of up to 71 °C. With no moving parts, no electricity, and no refrigerant, a vortex tube can produce refrigeration up to using only filtered compressed air at 100 PSI. A control valve in the hot air exhaust adjusts temperatures, flows and refrigeration over a wide range.
Vortex tubes are used for cooling of cutting tools during machining. The vortex tube is well-matched to this application: machine shops generally already use compressed air, and a fast jet of cold air provides both cooling and removal of the "chips" produced by the tool. This completely eliminates or drastically reduces the need for liquid coolant, which is messy, expensive, and environmentally hazardous.