Two-photon absorption
Two-photon absorption is the absorption of two photons of identical or different frequencies in order to excite a molecule from one state to a higher energy, most commonly an excited electronic state. The energy difference between the involved lower and upper states of the molecule is equal to the sum of the photon energies of the two photons absorbed. Two-photon absorption is a third-order process, typically several orders of magnitude weaker than linear absorption at low light intensities. It differs from linear absorption in that the optical transition rate due to TPA depends on the square of the light intensity, thus it is a nonlinear optical process, and can dominate over linear absorption at high intensities.
Two-photon absorption can lead to two-photon-excited fluorescence where the excited state produced by TPA decays by spontaneous emission to a lower energy state.
Background
The phenomenon was originally predicted by Maria Goeppert-Mayer in 1931 in her doctoral dissertation. Thirty years later, the invention of the laser permitted the first experimental verification of TPA when two-photon-excited fluorescence was detected in a europium-doped crystal. Soon afterwards, the effect was observed in cesium vapor and then in CdS, a semiconductor.and a fluorescence emission. The electron returns at ground state by another non-radiative deexcitation. The created pulsation is thus smaller that twice the excited pulsation
TPA is a nonlinear optical process. In particular, the imaginary part of the third-order nonlinear susceptibility is related to the extent of TPA in a given molecule. The selection rules for TPA are therefore different from one-photon absorption, which is dependent on the first-order susceptibility. The relationship between the selection rules for one-and two-photon absorption is analogous to those of Raman and IR spectroscopies. For example, in a centrosymmetric molecule, one- and two-photon allowed transitions are mutually exclusive, an optical transition allowed in one of the spectroscopies is forbidden in the other. In quantum mechanical terms, this difference results from the fact that the quantum states of such molecules have either + or - inversion symmetry, usually labelled by g and u. One photon transitions are only allowed between states that differ in the inversion symmetry, i.e. g <-> u, while two photon transitions are only allowed between states that have the same inversion symmetry, i.e. g <->g and u <-> u.
The relation between the number of photons - or, equivalently, order of the electronic transitions - involved in a TPA process and the order of the corresponding nonlinear susceptibility may be understood using the optical theorem. This theorem relates the imaginary part of an all-optical process of a given perturbation order with a process involving charge carriers with half the perturbation order, i.e.. To apply this theorem it is important to consider that the order in perturbation theory to calculate the probability amplitude of an all-optical process is. Since in the case of TPA there are electronic transitions of the second order involved, it results from the optical theorem that the order of the nonlinear susceptibility is, i.e. it is a process.
In the next paragraph resonant two photon absorption via separate one-photon transitions is mentioned, where the absorption alone is a first order process and any fluorescence from the final state of the second transition will be of second order; this means it will rise as the square of the incoming intensity. The virtual state argument is quite orthogonal to the anharmonic oscillator argument. It states for example that in a semiconductor, absorption at high energies is impossible if two photons cannot bridge the band gap. So, many materials can be used for the Kerr effect that do not show any absorption and thus have a high damage threshold.
Two-photon absorption can be measured by several techniques. Some of them are two-photon excited fluorescence. z-scan, self-diffraction or nonlinear transmission. Pulsed lasers are most often used because TPA is a third-order nonlinear optical process, and therefore is most efficient at very high intensities. Phenomenologically, this can be thought of as the third term in a conventional anharmonic oscillator model for depicting vibrational behavior of molecules. Another view is to think of light as photons. In nonresonant TPA two photons combine to bridge an energy gap larger than the energies of each photon individually. If there were an intermediate state in the gap, this could happen via two separate one-photon transitions in a process described as "resonant TPA", "sequential TPA", or "1+1 absorption". In nonresonant TPA the transition occurs without the presence of the intermediate state. This can be viewed as being due to a "virtual" state created by the interaction of the photons with the molecule.
The "nonlinear" in the description of this process means that the strength of the interaction increases faster than linearly with the electric field of the light. In fact, under ideal conditions the rate of TPA is proportional to the square of the field intensity. This dependence can be derived quantum mechanically, but is intuitively obvious when one considers that it requires two photons to coincide in time and space. This requirement for high light intensity means that lasers are required to study TPA phenomena. Further, in order to understand the TPA spectrum, monochromatic light is also desired in order to measure the TPA cross section at different wavelengths. Hence, tunable pulsed lasers are the choice of excitation.
Measurements
Absorption rate
describes the decay in intensity due to one-photon absorption:where are the distance that light traveled through a sample, the light intensity after traveling a distance x, the light intensity where the light enters the sample, and the one photon absorption coefficient of the sample, respectively. In two photon absorption, for an incident plane wave of radiation, the light intensity versus distance changes to
for TPA with light intensity as a function of path length or cross section as a function of concentration and the initial light intensity. The absorption coefficient now becomes the TPA coefficient.
Units of cross-section
The molecular two-photon cross-section is usually quoted in the units of Goeppert-Mayer , where 1 GM is 10−50 cm4 s photon−1. Considering the reason for these units, one can see that it results from the product of two areas and a time. The large scaling factor is introduced in order that 2-photon absorption cross-sections of common dyes will have convenient values.Development of the field and potential applications
Until the early 1980s, TPA was used as a spectroscopic tool. Scientists compared the OPA and TPA spectra of different organic molecules and obtained several fundamental structure property relationships. However, in late 1980s, applications started to be developed. Peter Rentzepis suggested applications in 3D optical data storage. Watt Webb suggested microscopy and imaging. Other applications such as 3D microfabrication, optical logic, autocorrelation, pulse reshaping and optical power limiting were also demonstrated.3D imaging of semiconductors
It was demonstrated that by using 2-photon absorption charge carriers can be generated spatially confined in a semiconductor device. This can be used to investigate the charge transport properties of such device.Microfabrication and lithography
One of the most distinguishing features of TPA is that the rate of absorption of light by a molecule depends on the square of the light's intensity. This is different from OPA, where the rate of absorption is linear with respect to input intensity. As a result of this dependence, if material is cut with a high power laser beam, the rate of material removal decreases very sharply from the center of the beam to its periphery. Because of this, the "pit" created is sharper and better resolved than if the same size pit were created using normal absorption.3D photopolymerization
In 3D microfabrication, a block of gel containing monomers and a 2-photon active photoinitiator is prepared as a raw material. Application of a focused laser to the block results in polymerization only at the focal spot of the laser, where the intensity of the absorbed light is highest. The shape of an object can therefore be traced out by the laser, and then the excess gel can be washed away to leave the traced solid.Imaging
The human body is not transparent to visible wavelengths. Hence, one photon imaging using fluorescent dyes is not very efficient. If the same dye had good two-photon absorption, then the corresponding excitation would occur at approximately two times the wavelength at which one-photon excitation would have occurred. As a result, it is possible to use excitation in the far infrared region where the human body shows good transparency.It is sometimes said, incorrectly, that Rayleigh scattering is relevant to imaging techniques such as two-photon. According to Rayleigh's scattering law, the amount of scattering is proportional to, where is the wavelength. As a result, if the wavelength is increased by a factor of 2, the Rayleigh scattering is reduced by a factor of 16. However, Rayleigh scattering only takes place when scattering particles are much smaller than the wavelength of light. When particles are larger, scattering increases approximately linearly with wavelength: hence clouds are white since they contain water droplets. This form of scatter is known as Mie scattering and is what occurs in biological tissues. So, although longer wavelengths do scatter less in biological tissues, the difference is not as dramatic as Rayleigh's law would predict.
Optical power limiting
Another area of research is optical power limiting. In a material with a strong nonlinear effect, the absorption of light increases with intensity such that beyond a certain input intensity the output intensity approaches a constant value. Such a material can be used to limit the amount of optical power entering a system. This can be used to protect expensive or sensitive equipment such as sensors, can be used in protective goggles, or can be used to control noise in laser beams.Photodynamic therapy
is a method for treating cancer. In this technique, an organic molecule with a good triplet quantum yield is excited so that the triplet state of this molecule interacts with oxygen. The ground state of oxygen has triplet character. This leads to triplet-triplet annihilation, which gives rise to singlet oxygen, which in turn attacks cancerous cells. However, using TPA materials, the window for excitation can be extended into the infrared region, thereby making the process more viable to be used on the human body.Optical data storage
The ability of two-photon excitation to address molecules deep within a sample without affecting other areas makes it possible to store and retrieve information in the volume of a substance rather than only on a surface as is done on the DVD. Therefore, 3D optical data storage has the possibility to provide media that contain terabyte-level data capacities on a single disc.Compounds
To some extent, linear and 2-photon absorption strengths are linked. Therefore, the first compounds to be studied were standard dyes. In particular, laser dyes were used, since these have good photostability characteristics. However, these dyes tend to have 2-photon cross-sections of the order of 0.1–10 GM, much less than is required to allow simple experiments.It was not until the 1990s that rational design principles for the construction of two-photon-absorbing molecules began to be developed, in response to a need from imaging and data storage technologies, and aided by the rapid increases in computer power that allowed quantum calculations to be made. The accurate quantum mechanical analysis of two-photon absorbance is orders of magnitude more computationally intensive than that of one-photon absorbance, requiring highly correlated calculations at very high levels of theory.
The most important features of strongly TPA molecules were found to be a long conjugation system and substitution by strong donor and acceptor groups. Therefore, many push-pull olefins exhibit high TPA transitions, up to several thousand GM. It is also found that compounds with a real intermediate energy level close to the "virtual" energy level can have large 2-photon cross-sections as a result of resonance enhancement.
Compounds with interesting TPA properties also include various porphyrin derivatives, conjugated polymers and even dendrimers. In one study a diradical resonance contribution for the compound depicted below was also linked to efficient TPA. The TPA wavelength for this compound is 1425 nanometer with observed TPA cross section of 424 GM.
Coefficients
The two photon absorption coefficient is defined by the relationso that
Where is the two-photon absorption coefficient, is the absorption coefficient, is the transition rate for TPA per unit volume, is the irradiance, is the Dirac constant, is the photon frequency and the thickness of the slice is. is the number density of molecules per cm3, is the photon energy, is the two-photon absorption cross section.
The SI units of the beta coefficient are m/W. If is multiplied by 10−9 it can be converted to the CGS system.
Due to different laser pulses the TPA coefficients reported has differed as much as a factor 3. With the transition towards shorter laser pulses, from
picosecond to subpicosecond durations, noticeably reduced TPA coefficient have been obtained.
In water
Laser induced TPA in water was discovered in 1980.Water absorbs UV radiation near 125 nm exiting the 3a1 orbital leading to dissociation into OH⁻ and H⁺. Through TPA this dissociation can be achieved by two photons near 266 nm. Since water and heavy water have different vibration frequencies and inertia they also need different photon energies to achieve dissociation and have different absorption coefficients for a given photon wavelength.
A study from Jan 2002 used a femtosecond laser tuned to 0.22 Picoseconds found the coefficient of D2O to be 42±5 10−11 whereas H2O was 49±5 10−11.
λ | pulse duration τ | |
315 | 29 | 4 |
300 | 29 | 4.5 |
289 | 29 | 6 |
282 | 29 | 7 |
282 | 0.18 | 19 |
266 | 29 | 10 |
264 | 0.22 | 49±5 |
216 | 15 | 20 |
213 | 26 | 32 |