Protein film voltammetry


In electrochemistry, protein film voltammetry is a technique for examining the behavior of proteins immobilized on an electrode. The technique is applicable to proteins and enzymes that engage in electron transfer reactions and it is part of the methods available to study enzyme kinetics.
Provided that it makes suitable contact with the electrode surface and provided that it is not denatured, the protein can be fruitfully interrogated by monitoring current as a function of electrode potential and other experimental parameters.
Various electrode materials can be used. Special electrode designs are required to address membrane-bound proteins.

Experiments with redox proteins

Small redox proteins such as cytochromes and ferredoxins can be investigated on condition that their electroactive coverage is large enough.
Electrochemical data obtained with small proteins can be used to measure the redox potentials of the protein's redox sites, the rate of electron transfer between the protein and the electrode, or the rates of chemical reactions that are coupled to electron transfer.

Interpretation of the peak current and peak area

In a cyclic voltammetry experiment carried out with an adsorbed redox protein, the oxidation and reduction of each redox site shows as a pair of positive and negative peaks. Since all the sample is oxidised or reduced during the potential sweep, the peak current and peak area should be proportional to scan rate. The same is true for experiments performed with non-biological redox molecules adsorbed onto electrodes. The theory was mainly developed by the French electrochemist Etienne Laviron in the 1980s,,.
Since both this faradaic current and the capacitive current increase in proportion to scan rate, the peaks should remain visible when the scan rate is increased. In contrast, when the redox analyte is in solution and diffuses to/from the electrode, the peak current is proportional to the square root of the scan rate.

Peak area

Irrespective of scan rate, the area under the peak is equal to, where is the number of electrons exchanged in the oxidation/reduction of the center, is the electrode surface and is the electroactive coverage. The latter can therefore be deduced from the area under the peak after subtraction of the capacitive current.

Peak shape

Slow scan rate
At slow scan rates there should be no separation between the oxidative and reductive peaks.
If the reaction is a simple electron transfer reaction, the peaks should remain symmetrical at fast scan rates. A peak separation is observed when the scan rate, where is the exchange electron transfer rate constant in Butler Volmer theory. Laviron equation ,, predicts that at fast scan rates, the peaks separate in proportion to. The larger or the smaller, the larger the peak separation. The peak potentials are, as shown by lines in fig 2B. Examining the experimental change in peak position against scan rate therefore informs on the rate of interfacial electron transfer.
Effect of coupled chemical reactions
Coupled reactions are reactions whose rate or equilibrium constant is not the same for the oxidized and reduced forms of the species that is being investigated. For example, reduction should favour protonation : the protonation reaction is coupled to the reduction at. The binding of a small molecule may also be coupled to a redox reaction.
Two cases must be considered depending on whether the coupled reaction is slow or fast.
In studies of enzymes, the current results from the catalytic oxydation or reduction of the enzyme's substrate.
The electroactive coverage of large redox enzymes is often too low to detect any signal in the absence of substrate, but the electrochemical signal is amplified by catalysis: indeed, the catalytic current is proportional to turnover rate times electroactive coverage. The effect of varying the electrode potential, the pH or the concentration of substrates and inhibitors etc. can be examined to learn about various steps in the catalytic mechanism.

Interpretation of the value of the catalytic current

For an enzyme immobilised on an electrode, the value of the current at a certain potential equates, where is the number of electrons exchanged in the catalytic reaction, is the electrode surface, is the electroactive coverage, and TOF is the turnover frequency.The latter can be deduced from the absolute value of the current only on condition that is known, which is rarely the case. However, information is obtained by analysing the relative change in current that results from changing the experimental conditions.
The factors that may influence the TOF are the mass transport of substrate towards the electrode where the enzyme is immobilised, the rate of electron transfer between the electrode and the enzyme, and the "intrinsic" activity of the enzyme, all of which may depend on electrode potential.
The enzyme is often immobilized on a rotating disk working electrode that is spun quickly to prevent the depletion of the substrate near the electrode. In that case, mass transport of substrate towards the electrode where the enzyme is adsorbed may not be influential.

Steady-state voltammetric response

Under very oxidising or very reducing conditions, the steady-state catalytic current sometimes tends to a limiting value which relates to the activity of the fully oxidised or fully reduced enzyme, respectively. If interfacial electron transfer is slow and if there is a distribution of electron transfer rates, the current keeps increasing linearly with potential instead of reaching a plateau; in that case the limiting slope is proportional to the turnover rate of the fully oxidised or fully reduced enzyme.
The change in steady-state current against potential is often complex.

Departure from steady-state

Another level of complexity comes from the existence of slow redox-driven reactions that may change the activity of the enzyme and make the response depart from steady-state. Here, slow means that the time scale of the activation is similar to the voltammetric time scale. If a RDE is used, these slow activations are detected by a hysteresis in the catalytic voltammogram that is not due to mass-transport. The hysteresis may disappear at very fast scan rates or at very slow scan rates.

Combining protein film voltammetry and spectroscopy

Conventional voltammetry offers a limited picture of the enzyme-electrode interface and on the structure of the species involved in the reaction. Complementing standard electrochemistry with other methods can provide a more complete picture of catalysis..