In medicine, a nasopharyngeal airway, also known as an NPA, nasal trumpet, or nose hose, is a type of airway adjunct, a tube that is designed to be inserted into the nasal passageway to secure an open airway. When a patient becomes unconscious, the muscles in the jaw commonly relax and can allow the tongue to slide back and obstruct the airway. This makes airway management necessary, and an NPA is one of the available tools. The purpose of the flared end is to prevent the device from becoming lost inside the patient's nose.

Sizes

As with other catheters, NPAs are measured using the French catheter scale, but sizes are usually also quoted in millimeters. Typical sizes include: 6.5 mm/28FR, 7.0 mm/30FR, 7.5 mm/32FR, 8.0 mm/34FR, and 8.5 mm/36FR.

Indications and contraindications

These devices are used by emergency care professionals such as EMTs and paramedics in situations where an artificial form of airway maintenance is necessary, but tracheal intubation is impossible, inadvisable, or outside the practitioner's scope of practice. An NPA is often used in conscious patients where an oropharyngeal airway would trigger the gag reflex. They are contraindicated in patients with severe facial trauma, as they may have an altered facial anatomy and inserting an NPA may cause additional harm to the patient.

Insertion

The correct size airway is chosen by measuring the device on the patient: the device should reach from the patient's nostril to the earlobe or the angle of the jaw. The outside of the tube is lubricated with a water-based lubricant so that it enters the nose more easily. The device is inserted until the flared end rests against the nostril.