Director telephone system
The director telephone system was a development of the Strowger or step-by-step switching system used in London and five other large cities in the UK from the 1920s to the 1970s.
A large proportion of telephone traffic in large metropolitan areas is outgoing traffic, and it is distributed over many exchanges. A non-director SXS exchange system is not suitable for these areas.
As the translation facility incorporated was similar to the register in common control systems, the director system incorporates two features of the Panel system, which was introduced in large American cities, and which were required regardless of the type of exchange system for these large areas which would have a mixture of manual and automatic exchanges for some years. Customer stations were assigned seven-digit numbers, with the first three digits spelling out the local exchange name; this expedited call handling particularly to and from manual exchanges. Direct or tandem junction routes to other exchanges could be allocated as required, with routing independent of the telephone number and able to be altered at any time to cater for traffic growth or the introduction of new local or tandem exchanges.
Each local exchange incorporated up to eight groups of directors which translated the first three digits comprising the exchange name into a pulse train of one to six digits, as required for each exchange and unique to that exchange. The translated digits were sent to the code selectors, and then the four numeric digits were sent to three switching stages in the terminating exchange. Hence local calls within the exchange and busy direct junction routes to exchanges with high traffic from that exchange could be trunked via one code selection stage, which reduced both the setting-up time and the total numbers of selectors required in the network. Distant exchanges which did not justify direct junction routes could be called via one or more tandem exchanges; being routed via one, two or three local code selectors in the originating exchange, one or more selectors in the tandem exchange, and finally the numeric selection stages in the terminating exchange for the last four digits, which were stored and forwarded without translation.
Numbering plan
The telephone numbering plan for the Director System assigned seven-digit telephone numbers to subscriber stations. The first three digits were encoded as the first three letters of the local exchange name. The translation map of letters to digits was displayed directly on the telephone rotary dial, by grouping the letters with the corresponding digits. The British letter arrangement was similar to American dials, except that the letters “O” mapped to digit 0, not 6: 1, 2 ABC, 3 DEF, 4 GHI, 5 JKL, 6 MN, 7 PRS, 8 TUV, 9 WXY, 0 OQ. The mapping of O and Q to 0 was to eliminate the possibility of a subscriber misdialling as a result of misreading a number.A subscriber in Wimbledon would be assigned the number ; the first three letters, written in capitals, indicated the exchange code to be dialled. The actual trains of pulses from the subscriber's dial were 9461234. The exchange code digits dialled by the calling subscriber were the same from any telephone in the London director area, which has a linked numbering scheme. Subscribers on manual exchanges asked for a number in the format, whether the called number was on a manual or automatic exchange.
The three-letter code was written in bold capitals if the caller should dial all seven digits. If written merely in capitals it indicated that the desired number was on an exchange which had not yet been converted to automatic working, and that the caller should dial only the initial three code digits, and wait to be connected by an operator. Later some of the remaining manual exchanges were equipped with Coded-Call Indicators which displayed the local digits dialled by the caller to the operator, The number would be listed as for an automatic subscriber with the first three letters in bold, and automatic subscribers would dial all seven digits. If an exchange was outside the Director linked-number area, the exchange name and number was in small type, e.g. Laindon 2263.
In a Director area there were 8 digits available for the A-digit letter of the exchange name, and 9 digits each for the B-digit and C-digit letters; hence there were a maximum of 648 exchange names, though in practice some ABC codes did not have a usable name equivalent, and by 1966 London with 350 exchanges was running out of exchange names. Special Service numbers apart from “0” for operator used a three-letter exchange name; e.g. TOL, TRU, DIR, TIM, ENG, or UMP.
Equipment
To make a call, the subscriber's uniselector seizes a free first code selector, which in turn seizes an A-digit selector via an A-digit hunter uniselector. The A-digit selector returns dial tone, steps to the first dialled digit and searches for a free director from that group. The director includes a two-motion selector – the BC switch – which steps vertically and then horizontally according to the two BC digits. This selector has six banks to permit up to six pulse trains to be generated by the director to step the code selectors; the bank contacts are strapped via a translation field to indicate the digit required. The pulse train output begins after the C-digit is received from the subscriber's telephone. This is generated under the control of the send switch uniselector as it searches for the marks provided by the translation field straps for the exchange code received. Meanwhile, the subscriber has continued to dial and the four digits of the numerical portion of the number are stored on four more uniselectors. These set up four more marks, and after completing the output of the code translation the send switch uniselector searches for them in turn in order to forward the numerical digits unchanged to step the numerical selectors at the terminating exchange.Calls to manual exchanges and calls to special service like “0” for operator or “999” for emergencies do not require any numeric digits.
The holding time of the A-digit selector and director will depend on the number and length of code digits to be sent, and whether numeric digits are also to be sent, but averages 20 seconds. On a call to the operator via digit “0” which has already been received by the A-digit selector and requires no more than four routing digits and no numeric digits, the holding time will be only 2 or 3 seconds. As traffic to the operator via digit “0” is small, this level on the A-digit selector does not have its own group of directors; one or more of the other groups of directors is equipped with the necessary manual board facilities. Seizure of one of these directors via level "0" passes a discrimination signal to it which causes it to pulse out the routing digits to give access to the operator with no further dialling required by the subscriber.
For calls to manual local exchanges with CCI equipment to display the called number to the operator, the equipment required at the manual exchange and the director equipment holding time can be minimised by using storage equipment at the automatic exchange which holds the number information until manual exchange equipment is available.
The A-digit selector, BC switch and particularly the send switch uniselector of the director were worked much harder than selectors in the switching train which were held for the duration of the call, and the noise in the vicinity of director racks in the busy hour could be unbearable. An experimental “all-relay” director was developed in the 1950s to try to reduce the amount of maintenance the directors needed. Before they were replaced by electronic exchanges, some director exchanges had the director equipment replaced by electronic directors using CMOS technology which controlled the exchange selectors, with economies in space and maintenance.
Code selectors
The first code selectors had levels for local exchange calls and calls to the local tandem exchange. An exchange with up to 23 outgoing routes would require a second code selection stage on some calls, and for more outgoing routes some third selection stages. But as a nearby business exchange might have 50 TU in the BH, and more distant exchanges might have only 2 or 3 TUs, the busy routes should be on the first code selectors and the least busy routes only via a second and perhaps a third selection stage. Hence for a hypothetical example with 30 outgoing routes, three schemes are possible with three second and no third code selector groups, two second and one third code selector groups, and one second and two third code selector groups. The number of switches for the hypothetical traffic distribution is 348, 302 and 315 switches, i.e. scheme B is the optimum; but each exchange must be calculated individually. The busy routes should also be allocated to the lower levels on the selectors to minimise setting-up time and also the number of operations of the mechanism and hence the wear on them.Local call metering must be done at the originating exchange, and when local calls were charged by distance it was preferable for the first code selector levels to determine the number of unit fees required. The fee was 1 unit up to 5 miles, 2 units 5 to miles, 3 units to miles, and 4 units to 15 miles.
Preparation for director service
Before director service could be introduced to any exchange in the network, all subscriber numbers were made into the 3L-4N format, with any two or three-digit local numbers rounded up to 4 numeric digits. The exchange names were changed if necessary, as the same network cannot have exchanges called BRIxton and CRIcklewood, which both correspond to 274. As the first digit “0” is used for operator access, an exchange name cannot start with the letters “O” or "Q". The letter “Z” is not included on the dial, so the first three letters of an exchange name cannot include it.In smaller director areas outside London some A-digit levels could be combined so that local director exchanges only needed three or four groups of directors instead of eight, with greater efficiency from the larger groups of directors. A hypothetical area with 30 exchanges could be served by three groups of directors serving A-digit levels 2 & 3; 4 & 7, and 5, 6 & 8. But it was not possible to have exchanges called PERivale and TERminus in a director area where levels 7 and 8 were combined, and hence in these smaller areas, requirements for additional exchange names must be considered.
Before a manual exchange was converted to automatic, changes to allocated numbers to facilitate PBX hunting groups were required. In SXS automatic exchanges only some number groups have PBX hunting facility, and within those number groups the main and other numbers in a hunting group have to be in a certain order. If TUDor 2725 was to be the listed number subsequent numbers must be 2726, 2727, 2728 2729 & 2720; and the PBX hunting group on 2725 is limited to a maximum of 6 incoming lines. A PBX group with 10 PBX-hunting lines would commence with 2721 to 2720, and PBX hunting groups requiring more than 10 incoming lines would be served by special 11-and-over PBX final selectors which could search over several levels in succession.
In practice to save space 200-outlet final selectors were almost always used in preference to 100-outlet; the selectors switched to the alternate wipers, or not as appropriate, depending on which preceding selector stage seized them. This allowed a PBX group to have up to 20 lines without the need of 11-and-over PBX final selectors. Moreover, if these selectors were used, the PBX group could have up to 200 lines, and the final selectors in the group were arranged so that different selectors searched over the lines in a different order to reduce waiting times for callers.
Any two-party numbers also needed to be served by two-party or shared service equipment. The two subscribers on a two-party line would have separate three-letter then four digit numbers in a special number group, and had selective ringing to the party required only.
The London director area
In 1927 Holborn, the first director automatic exchange in London, was cutover at midnight on Saturday 12 November. As it was a largely business exchange, most subscribers did not use the new system until Monday 14 November. The changeover was successful, although there were some delays as the subscribers were not familiar with using a dial phone. BIShopgate and SLOane exchanges were to follow in six weeks, followed by WEStern and MONument exchanges. The London area contained 80 exchanges, and full conversion would take many years.Holborn exchange had 9,400 subscribers and had 222 directors, each of which on average handled 72 calls in the busy hour and be held for 20 seconds. Holborn was also a tandem exchange for calls to and from local manual exchanges, so that the tandem traffic from manual exchanges was combined with traffic from automatic exchanges. Handling local calls between manual exchanges via a third operator at a tandem exchange is uneconomic, but without tandem switching each manual exchange would require direct junctions to every other manual exchange. In London there were 73 manual exchanges within of Oxford Circus, of which twenty had coded-call indicator equipment which displayed the number dialled to the local manual exchange operator, and the rest were to be equipped shortly.
By 1950 the London director system had 75 exchanges within a radius of Oxford Circus and a further 65 in the 5–10 miles belt; and in Greater London i.e. within of Oxford Circus there were 237 exchanges altogether. London had some exchange buildings containing two separate exchanges, as the number of customer lines exceeded 10,000; e.g. CROydon and MUNicipal in Scarbrook Road.
The rotary system had been proposed for London by Bell engineers, who had developed the panel and rotary systems in the 1900s; manufactured in the United States and Europe respectively. The panel system with large switches was more suitable for a densely populated area like New York, and with outer areas of London having smaller exchanges they had proposed the rotary system for London. However the director system had the advantage of using equipment items similar to the SXS exchanges being used in smaller British cities and towns, and would be manufactured in Britain from the outset. It was also possible to convert a local SXS exchange to a director exchange.
While a director area had a maximum of 648 exchange names, in practice some numbers do not have a usable name equivalent; unusable ABC digits would be 688 or 555. London was running out of usable names with 350 exchanges by 1965; this was one reason for the change to all-figure dialling in 1966. This problem was sidestepped to some degree by using otherwise unusable codes to give access to the fringe non-director exchanges from the director area. For example, in London callers to South Mimms were told to dial SM6 followed by the four-digit South Mimms number; callers to Uxbridge numbers were told to dial UX followed by the five-digit Uxbridge number. In this latter case the first digit of the Uxbridge number rotated the BC switch of the director and was absorbed in specifying the translation; the last digit of the translation then regenerated the first digit of the Uxbridge number.
Other director cities
The director system was introduced in London, and then in Manchester, Birmingham, Glasgow, Liverpool, and Edinburgh. While London initially included all exchanges within miles of Oxford Circus, other cities initially included all exchanges within 7 miles radius from the city centre, and was then extended to include larger exchanges within miles radius from the centre. Generally it was policy to install director equipment where the total number of subscribers was expected to be greater than 60,000 lines within 30 years.In cities outside London, it was possible to avoid the installation of Coded-Call Indicator equipment at manual exchanges by converting to automatic in stages with the issue of a new directory, e.g. converting groups of six exchanges at 12-month intervals; this was done in Liverpool, Birmingham, Glasgow and Edinburgh.
In 1950 Glasgow had 35 exchanges within 7 miles of the centre of the city, several of two units, and 11 of them were within 2 miles of the centre.
By the time the director system was superseded in the UK by all-figure dialling from March 1966, London had almost exhausted all possible, usable combinations of letters. While this was far from the case in the provincial cities, the crossover to all-figure dialling was still a sizeable operation in Manchester, Birmingham and Glasgow.