Amperometry in chemistry is detection of ions in a solution based on electric current or changes in electric current. Amperometry is used in electrophysiology to study vesicle release events using a carbon fiber electrode. Unlike patch clamp techniques, the electrode used for amperometry is not inserted into or attached to the cell, but brought in close proximity of the cell. The measurements from the electrode originate from an oxidizing reaction of a vesicle cargo released into the medium. Another technique used to measure vesicle release is capacitive measurements.
History
or amperometric detection as it was first used in ion chromatography was single-potential or DC amperometry, useful for certain electrochemically active ions such as cyanide, sulfite, and iodide. The development of pulsed amperometric detection for analytes that fouled electrode surfaces when detected eventually helped create a new category of ion chromatography for the determination of carbohydrates. Another advancement, known as integrated amperometry, has increased the sensitivity for other electrochemically active species, such as amines and many compounds that contain reduced sulfur groups, that are sometimes weakly detected by PAD. It was established that neurotransmitters could be electrochemically detected by placing a carbon electrode into tissue and recording the current from oxidizing neurotransmitters. One of the first measurements was made using an implantedcarbon fiber electrode in the neostriatum of rats. Further work was done in chromaffin cells to investigate catecholamine release from large dense core vesicles.
Detection methods
Single-potential amperometry
Any analyte that can be oxidized or reduced is a candidate for amperometric detection. The simplest form of amperometric detection is single-potential, or direct current, amperometry. A voltage is applied between two electrodes positioned in the column effluent. The measured current changes as an electroactive analyte is oxidized at the anode or reduced at the cathode. Single-potential amperometry has been used to detectweak acid anions, such as cyanide and sulfide, which are problematic by conductometric methods. Another, possibly more important advantage of amperometry over other detection methods for these and other ions, such as iodide, sulfite, and hydrazine, is specificity. The applied potential can be adjusted to maximize the response for the analyte of interest while minimizing the response for interfering analytes
Pulsed amperometry
An extension of single-potential amperometry is pulsed amperometry, most commonly used for analytes that tend to foul electrodes. Analytes that foul electrodes reduce the signal with each analysis and necessitate cleaning of the electrode. In pulsed amperometric detection, a working potential is applied for a short time, followed by higher or lower potentials that are used for cleaning the electrode. The current is measured only while the working potential is applied, then sequential current measurements are processed by the detector to produce a smooth output. PAD is most often used for detection of carbohydrates after an anion exchange separation, but further development of related techniques show promise for amines, reduced sulfur species, and other electroactive compounds.
Principle
In order to record vesicle fusion, a carbon fiber electrode is brought close to the cell. The electrode is held at a positive potential, and when the cargo from a fused vesicle is near the electrode, oxidation of the cargo transfers electrons to the electrode. This causes a spike, the size of which can be used to estimate the number of vesicles, and the frequency gives information about the release probability.